1855   sboClass Val in SCL example

Created: 01 Dec 2022

Status: Editorial

Part: Part 8-1 (2020; Edition 2.1)

Links:

Page: 198

Clause: Annex G

Paragraph: SCL example

Issue

In the SCL example, there are two instances where the Val element is written as 'operated-once'.

<DA name="sboClass" fc="CF" bType="Enum" dchg="true" type="sboClass" valKind="RO">
<Val>operated-once</Val>
</DA>

Proposal

The Val element should be written as 'operate-once', as documented in 'IEC_61850-7-3_2007B3.nsd'.

<Enumeration name="SboClassKind">
<Literal name="operate-once" literalVal="0">
<Literal name="operate-many" literalVal="1"/>
</Enumeration>

Discussion Created Status
Approved Editorial 12 Dec 23 Editorial
I agree. 20 Dec 22 Approval (Editoral)
Agree with the editorial change of Annex G.
Replace the 4 occurences of
[Val]operated-once[/Val]
with
[Val]operate-once[/Val]
20 Dec 22 Approval (Editoral)

 

Privacy | Contact | Disclaimer

Tissue DB v. 23.12.13.1