Part 7-3 (2003)

Technical Issue Subject Cat Status Page Clause Paragraph Created Last Comment
1199 Allow INT32 for CDC BCR IntOp In Force (green) 26 7.3.8 Table 20 (BCR CDC) 05 Jan 14 06 May 14
619 CDC for Description settings Ed2 Not Applicable 3 1 1 27 May 08 30 May 08
615 dataNs, cdcNs, lnNs definitions Ed2 Ballot Period 22 table 12 27 Mar 08 19 May 08
582 BCR actVal as INT128 Ed2 In Force (green) 26 7.3.8 14 Nov 07 27 Feb 08
581 originator category Ed2 Not Applicable 20 6.8 Originator Table 8 – Values for orCat 08 Nov 07 03 May 17
542 deadbands requires RangeConfig implementation Ed2 Not Applicable 18 6.5 RangeConfig 05 Jul 07 06 Jul 07
531 angRef Ed2 Not Applicable 23 Table 23 26 Apr 07 27 Apr 07
530 range Ed2 Not Applicable 28 & 29 Table 22 & 23 26 Apr 07 26 Apr 07
525 subMag and instMag in CDC MV Ed2 Ballot Period 7.4.2 Table 22 24 Apr 07 26 Apr 07
519 Add new unit to table A4 Ed2 In Force (green) Annex A 20 Apr 07 29 May 07
489 Input for Logical Nodes: Data Object binding Ed2 Not Applicable 26 Mar 07 16 Oct 20
483 Data and DataAttributes in WYE and DEL Ed2 In Force (green) 27, 31, 32, 51 7.4.1, 7.4.5, 7.4.6, 8 Tables 21, 25, 26, 49 16 Mar 07 29 May 07
482 Quality evaluation of a Vector Ed2 Future Improvement 29 7.4.3 Table 23 15 Mar 07 29 May 07
469 oper timeout missing in controlable CDC Ed2 In Force (green) 09 Feb 07 09 Apr 07
439 lower limit of stepSize in ASG Ed2 In Force (green) 47 7.8.2 Analogue setting (ASG) Table 43 09 Nov 06 29 May 07
437 Overturn Tissue 173 Ed2 Not Applicable 26 Oct 06 27 Oct 06
424 DAI paramRev etc. - Tissue #13 from part6 Ed2 In Force (green) 50 7.9.3 11 Oct 06 25 Oct 06
414 Multiplier "Petra" Ed2 In Force (green) 62 Table A.5 21 Sep 06 15 Apr 07
375 Directional loop activation information Ed2 In Force (green) 25 7.3.6 29 Aug 06 29 May 07
359 Range Min/Max configuration as new range states Ed2 In Force (green) 55 8 Table 48 13 Aug 06 29 May 07
358 Descrition text for range attribute values (normal, high, low, ...) Ed2 In Force (green) 28 / 55 7.4.2 / 8 Tables 22 and 23 / 48 13 Aug 06 29 May 07
340 Enumeration CDC Ed2 In Force (green) 08 Jul 06 28 Mar 09
330 CDC HMV, HWYE, HDEL Ed2 In Force (green) 7.4.8, 7.4.9, 7.4.10 13 Jun 06 29 May 07
328 New unit for frequency functions Ed2 In Force (green) 61 Table A.4 30 May 06 29 May 07
327 More new types of unit Ed2 In Force (green) 61 Table A.4 30 May 06 29 May 07
312 Clarification on use of CURVE and CSD Ed2 Not Applicable 7.8.3 and 7.9.4 11 Apr 06 29 May 07
274 Types of CURVE attributes Ntp Not Applicable 48 7.8.3 Table 44 16 Dec 05 16 Dec 05
270 WYE and DEL rms values IntOp In Force (green) 31 7.4.5, 7.4.6 09 Dec 05 19 Nov 10
266 Open enumeration for range Ed2 In Force (green) 28 and more 7.4.2 and more Table 22 and more 02 Dec 05 29 May 07
265 Quality extension Ed2 Ballot Period 11 6.2.1 29 Nov 05 03 Mar 10
247 Miss % representation Ed2 In Force (green) 60-62 Table A 04 Nov 05 15 May 06
240 New type of SI unit Ed2 In Force (green) 61 Table A.4 11 Oct 05 15 May 06
239 Conflict of LPL definitions with requirements of Namespace Ed2 In Force (green) 22 7.2 Table 12 11 Oct 05 15 May 06
223 discuss 144 CDC=APC Ntp Not Applicable 28 Sep 05 03 Oct 05
219 operTm in ACT IntOp In Force (green) 24 7.3.5 Table 17 26 Sep 05 17 Nov 05
217 CDC for LN Inputs Ed2 In Force (green) 23 Sep 05 16 Oct 20
214 setMag in ASG,APC Ntp Not Applicable 47,44 7 7.8.2, 7.6.2 22 Sep 05 03 Oct 05
213 setMag in ASG,APC Ntp In Force (green) 47,44 7 7.8.2, 7.6.2 22 Sep 05 17 Nov 05
205 Device name plate - missing description "d" and "dU" Ed2 In Force (green) 49 7.9.2 table 46 14 Sep 05 17 Nov 05
204 Reporting of setting values Ed2 In Force (green) 45-48 7.7 and 7.8 14 Sep 05 27 Mar 06
182 Typo in Table A2 Ed2 In Force (green) 60 Annex A Table A2 10 Aug 05 10 Aug 05
171 Enums from 7-4 Ed2 In Force (green) 24, 40, 46 24 Jun 05 28 Mar 09
164 Deadband on range limits Ed2 In Force (green) 17 6.5 12 May 05 12 Aug 05
161 CDCs for Setting - conditions Ed2 In Force (green) 10 5, table 03 May 05 12 Aug 05
138 harmonization of titles Ed2 In Force (green) 7.3.1 31 Mar 05 22 May 05
68 New CDC ACI Ed2 In Force (green) General 15 Mar 05 14 Jun 05
67 comments on (old) 9, 10, 11 ,12 Ntp Not Applicable Several issues 15 Mar 05 02 Apr 05
66 Frequency of power system Ntp Not Applicable General 15 Mar 05 02 Apr 05
65 Deadband calculation of a Vector and trigger option Ed2 In Force (green) General 15 Mar 05 27 Apr 07
64 Deadband calculation Ntp In Force (green) 53 15 Mar 05 15 Mar 05
63 mag in CDC CMV IntOp In Force (green) General 15 Mar 05 31 Mar 05
62 RMS and avg Values Ntp In Force (green) General 15 Mar 05 17 Nov 05
61 Units of type Unit? Ntp In Force (green) several 15 Mar 05 15 Mar 05
60 Services missing in tables Ed2 In Force (green) Table 13/21 and other 15 Mar 05 15 Mar 05
59 Missing services in tables Ntp In Force (green) 7.3.1 Table 13, 21 and other 15 Mar 05 11 May 05
58 Typeo in table Ed2 In Force (green) 21 6.11 Table 11 15 Mar 05 15 Mar 05
57 Gaps in Note numbers Ed2 In Force (green) 51ff 8 Table 49 15 Mar 05 15 Mar 05
56 No service Synchrocheck Ed2 In Force (green) 7.5.1 Table 31 15 Mar 05 15 Mar 05
55 Ineut = Ires ? IntOp In Force (green) 7.4.5 Table 25 15 Mar 05 29 Mar 05
54 Point def xVal, not cVal IntOp In Force (green) 6.11 below Table 11 15 Mar 05 15 Mar 05
28 Definition of APC IntOp In Force (green) 7.6.2 11 Mar 05 22 May 05

 

Privacy | Contact | Disclaimer